GAF Master Elite Contractor inspection GAF Timberline HD roof installation for Golden Pledge Warranty.

Gaf Timberline HDZ Pewter Color – Front View of Roof

  1. 1
    Cupping Shingles

    Cupping shingles at the edge of the roof. Also, the starter is not lapped properly, with a 6-inch overlap. Cupping is a problem because it can cause leaks. The starter is a mixed install but not difficult to repair.

    Cupping Shingles

    Go To Pin
  2. 2
    Improper Nailing

    Image number 1 shows the shingle stagger appears to be correct, or close enough at least. There is an exposed nail where the circle is.

    Improper Nailing

    Image number 2 is very strange, not sure what this piece of shingle is doing nailed like this.

    Improper Nailing

     These 2 images are in the same area of the roof.

    Go To Pin
  3. 3
    No Cobra Vent Installed

    No ridge vent installed on this job.  GAF cobra vent would have been the proper material to use.  Instead, the crew maintained old power vents.  These certainly wouldn’t ventilate the entire home.

    https://youtu.be/EwBLTmWTcU0

    Go To Pin
  4. 4
    Video Walk Through

    An Introduction To Lead Symphony.

     

    Go To Pin

Rear slope of this new roof

  1. 1
    Valley Nail Spacing Incorrect

    Some valley nails are inside of 6 inches, this appears to be a leak potential.

    Click the link below to see the Advisory.

    GAF Steep Slope Technical Advisory

    Valley Nail Spacing Incorrect Valley Nail Spacing Incorrect

    Go To Pin
  2. 2
    Improper Nail Pattern On Entire Roof

    Shingle nail patterns are bad.  They are too close to the union.

    Improper Nail Pattern On Entire Roof

     

    This is a major problem and will cause leaks in the roof.  The nail pattern is not properly spaced over the entire roof.

    Technical PDF From GAF On Improper Driven Nails

    Proper nail patterns from GAD Pro Field Guide:

     

    Improper Nail Pattern On Entire Roof

    Go To Pin

Chimney Flashing is a problem and will Leak

  1. 1
    The chimney is not flashed

    The left side of the chimney is not step flashed at all.

    The chimney is not flashed The chimney is not flashedThe chimney is not flashed

    Go To Pin
  2. 2
    Chimney

    Notice on the right side of the chimney does have step flashing, but the metal appears old, and step flashing looks to be nailed wrong.

    Chimney

    Chimney

    Chimney

    Go To Pin